About TiNiServicesProducts


 
ERM
PRODUCTS


ERM Selection
Guide


ERM Concept

ERM Applications

E500
Specification


E1000
Specification


E2000
Specification


E4000
Specification


Load Feedback

Customer List

 ERM
 Video Demo

 ERM-4000
 

The E4000 is capable of releasing loads up to 4000 lbs as would be generated during torque up of the 3/8-24 bolt which threads into the actuator coupler.

Features include:

  

• Redundant TiNi Trigger
• Auto Shut Off Switch
• Simple One-Step Manual Reset*
• Fast Actuation (see below)

 

Custom configurations are readily attainable.

See Custom Actuators

 

 *Reset Tool Provided by TiNi Aerospace, Inc. 
 

Function Time @ 23°C
Specifications

 
Max Load
17793 N
(4000 lb-f)
Operational Current
2.75 to 8.75 A
Actuator Resistance*
2.5 ± 0.3 Ω
Power Consumption
40W @ 4A
Mass
430g
(15.2oz)
Life
MIN 50 Cycles
Max Operating Temp
+70°C
(158°F)
Min Operating Temp
-60°C
(-76°F)
Cable Length

457mm

(18 in.)
Cable Type
22 AWG M22759/43

* Actuator resistance can be readily increased to accommodate higher operating voltages. Customer may specify a value up to 50 ohms.